The
ARS-12
is
our
most
sensitive
angular
rate
sensor.
Designed
to
eliminate
jitter
from
airborne
and
space
borne
mirrors,
optical
systems
or
lasers,
and
for
accurate
line-of-sight
imaging
platform
stabilization,
the
ARS-12
can
measure
vibrations
and
angular
motions
as low
as 50
nanoradians.
This
product
has very
high
sensitivity
and
a
very low
noise
floor.
The
stainless
steel
housing
and
mounting
plate
make a
rugged
assembly,
able to
operate
accurately
after an
800g
shock
load.
Its
compact
size
and mass
allow
use in very
small
spaces.
The
ARS-12
has a
wide,
usable
frequency
range
from
less
than
1
to
more
than
1,000
Hz. The
ARS-12
is
available
in
three
standard
ranges
for
angular
rate
measurement
and
three
standard
ranges
for
angular
displacement
measurement.
Export
Application/License
Information |

ARS-12B MHD Angular Rate Sensor
View
.pdf
format.
 |
Custom scale
factors and ranges are available.
|
|
|
|
ATA Sensors' patented MHD angular motion
sensors utilize the finest materials and
workmanship combined in durable packages that
feature:
• No moving parts
• Dynamic range > 100 dB
• Low power consumption
• Low cross axis angular sensitivity
• Low linear acceleration
sensitivity
• Integral electronics/low noise
• High survivable shock
limits
• Superior applications
support
• One-year warranty against defects in
materials and workmanship on sensors,
90 days on cables.
|
|
|
Specifications
|
|
|
ARS-12B MHD
Angular Rate Sensors |
|
|
|
Dynamic
View
.pdf
format.
|
|
ARS-12B Angular Rate Standard Ranges1 |
± 1 rad/sec |
± 100 mrad/sec |
± 10 mrad/sec |
|
ARS-12B Angular Displacement Standard Ranges1 |
± 10 mrad |
± 1 mrad |
± 100
mrad |
|
ARS-12B Angular Rate Standard
Scale Factors2 |
10
V/rad/sec |
100
V/rad/sec |
1,000
V/rad/sec |
|
ARS-12B Angular Displacement Standard
Scale Factors2 |
1,000
V/rad |
10,000
V/rad |
100,000
V/rad |
|
Bandwidth |
1
to 1000 Hz |
|
Cross-axis Angular Error |
< 2 % |
|
Linear Acceleration Sensitivity |
< 5 mrad/sec/g
|
|
Noise Equivalent Rate |
<8 microradians/s (rms) |
|
Noise Equivalent Angle |
< 100 nanoradians (rms, 1-1000 Hz) |
|
|
< 50 nanoradians (rms, 2-1000 Hz) |
|
Non-linearity |
< 0.1 % |
|
Temperature Coefficient3 |
< 0.4 % Scale Factor / ºC |
|
Electrical |
|
Power Dissipation |
< 0.5 Watts |
|
Output Impedance |
< 100 Ohms |
|
Grounding4 |
Case isolated from signal common by 1MΩ
minimum |
|
Wiring |
|
ARS-12B |
|
Red Lead |
+Power (+5 Vdc
to +15
Vdc) |
|
White Lead |
-Power (-5 Vdc
to -15
Vdc) |
|
Black Lead |
Power and Signal Common (0 Vdc) |
|
Yellow Lead |
Signal |
|
Environmental |
|
Temperature – operating |
-35
to +60
ºC (-31
to +140
ºF) |
|
Temperature - Non-operating |
-35
to +60
ºC (-31
to +140
ºF) |
|
Linear Acceleration5, Max.
Operating |
500
g
any axis |
|
Linear Acceleration5, Max.
Survivable |
800
g
any axis |
|
|
 |
 |
Notes:
1. Based on a +/-
10V
output
voltage
swing.
2. Measured
@ 10 Hz.
3. Percent change
in Scale
Factor
per ºC
@ 100
Hz.
4.
Signal
common
may be
connected
to case
if
required.
5.
Peak,
100 Hz
half
sine. |
|
| |
|