Printable
.pdf format.
For the
ARS-01, the leads from the
CA-01
cable should be connected as follows:
|
Red Lead
|
+5 VDC to +15 VDC
|
|
White Lead |
-5 VDC to –15 VDC
|
|
Black Lead
|
Power and Signal
Common (0 VDC)
|
|
Yellow Lead
|
Signal
|
For the
ARS-01S, the leads from the
CA-01
cable should be connected as follows:
|
Red Lead
|
+10 VDC
|
|
White Lead |
Power Common (0
VDC)
|
|
Black Lead
|
Signal Common (+5
VDC Internally Generated Reference Voltage)
|
|
Yellow Lead
|
Signal
|
For the
ARS-06, the leads from the CA-06
cable should be connected as follows:
|
Red Lead
|
|
|
White Lead |
|
|
Black Lead
|
|
|
Yellow Lead
|
|
For the
ARS-06S, the leads from the CA-06
cable should be connected as follows:
|
Red Lead
|
|
|
White Lead |
|
|
Black Lead
|
|
|
Yellow Lead
|
|
For the
ARS-09, the leads should be connected as
follows:
|
Red Lead
|
+5 VDC to +15 VDC
|
|
White Lead |
-5 VDC to –15 VDC
|
|
Black Lead
|
Power and Signal
Common (0 VDC)
|
|
Yellow Lead
|
Signal
|
For the
ARS-09S, the leads should be connected as
follows:
|
Red Lead
|
+8 VDC
|
|
White Lead |
Power Common (O
VDC)
|
|
Black Lead
|
Signal Common
(+4.1 VDC Internally Generated Reference Voltage)
|
|
Yellow Lead
|
Signal
|
For the
ARS-12B,
the leads should be connected as follows:
|
Red Lead
|
+5 VDC to +15 VDC
|
|
White Lead |
-5 VDC to –15 VDC
|
|
Black Lead
|
Power and Signal
Common (0 VDC)
|
|
Yellow Lead
|
Signal
|
For the
Dynacube™,
the leads from the
CA-04A cable should be connected as
follows:
|
Red Lead
|
+5 VDC to +15 VDC
|
|
White Lead |
-5 VDC to –15 VDC
|
|
Black Lead
|
Power and Signal
Common (0 VDC)
|
|
Brown Lead
|
X-Axis Signal
|
|
Orange Lead
|
Y-Axis Signal
|
|
Yellow Lead
|
Z-Axis Signal
|
For the
Dynacube -S,
the leads from the
CA-04A cable should be connected as
follows:
|
Red Lead
|
+10 VDC
|
|
White Lead |
Power Common (0 VDC)
|
|
Black Lead
|
Signal Common (+5
VDC Internally Generated Reference Voltage)
|
|
Brown Lead
|
X-Axis Signal
|
|
Orange Lead
|
Y-Axis Signal
|
|
Yellow Lead
|
Z-Axis Signal
|
|