Printable
.pdf format.
For the
ARS-01, the leads from the CA-01
cable should be connected as follows:
|
Red Lead |
+5 VDC to +15 VDC |
|
White Lead |
-5 VDC to –15 VDC |
|
Black Lead |
Power and Signal
Common (0 VDC) |
|
Yellow Lead |
Signal |
For the
ARS-01S, the leads from the CA-01
cable should be connected as follows:
|
Red Lead |
+10 VDC |
|
White Lead |
Power Common (0
VDC) |
|
Black Lead |
Signal Common (+5
VDC Internally Generated Reference Voltage) |
|
Yellow Lead |
Signal |
For the ARS-03, the
leads from the CA-01 cable should be connected as follows:
|
Red Lead |
+5 VDC to +15 VDC |
|
White Lead |
-5 VDC to –15 VDC |
|
Black Lead |
Power and Signal
Common (0 VDC) |
|
Yellow Lead |
Signal |
For the ARS-04E, the
leads from the CA-01 cable should be connected as follows:
|
Red Lead |
+5 VDC to +15 VDC |
|
White Lead |
-5 VDC to –15 VDC |
|
Black Lead |
Power and Signal
Common (0 VDC) |
|
Yellow Lead |
Signal |
For the ARS-04R, the
leads should be connected as follows:
|
Red Lead |
+5 VDC to +15 VDC |
|
White Lead |
-5 VDC to –15 VDC |
|
Black Lead |
Power and Signal
Common (0 VDC) |
|
Yellow Lead |
Signal |
For the ARS-06, the leads from the CA-06 cable should be
connected as follows:
|
Red Lead |
|
|
White Lead |
|
|
Black Lead |
|
|
Yellow Lead |
|
For the ARS-06S, the
leads from the CA-06 cable should be connected as follows:
|
Red Lead |
|
|
White Lead |
|
|
Black Lead |
|
|
Yellow Lead |
|
For the ARS-07, the
leads from the CA-01 cable should be connected as follows:
|
Red Lead
|
+5 VDC to +15 VDC |
|
White Lead |
-5 VDC to –15 VDC |
|
Black Lead
|
Power and Signal
Common (0 VDC) |
|
Yellow Lead |
Signal |
For the ARS-09, the
leads should be connected as follows:
|
Red Lead |
+5 VDC to +15 VDC |
|
White Lead |
-5 VDC to –15 VDC |
|
Black Lead |
Power and Signal
Common (0 VDC) |
|
Yellow Lead |
Signal |
For the ARS-09S, the
leads should be connected as follows:
|
Red Lead
|
+8 VDC |
|
White Lead |
Power Common (O
VDC) |
|
Black Lead |
Signal Common
(+4.1 VDC Internally Generated Reference Voltage) |
|
Yellow Lead |
Signal |
For the ARS-12, the
leads should be connected as follows:
|
Red Lead
|
+5 VDC to +15 VDC |
|
White Lead |
-5 VDC to –15 VDC |
|
Black Lead |
Power and Signal
Common (0 VDC) |
|
Yellow Lead |
Signal |
For the ARS-14, the
leads should be connected as follows:
|
Red Lead |
|
|
White Lead |
|
|
Black Lead |
|
|
Yellow Lead |
|
For the ARS-15, the
leads should be connected as follows:
|
Red Lead |
|
|
White Lead |
|
|
Black Lead |
|
|
Yellow Lead |
|
For the DMHD-01, the
leads should be connected as follows:
|
Red Lead |
|
|
White Lead |
|
|
Black Lead |
|
|
Yellow Lead |
|
For the Dynacube™, the
leads from the CA-04A cable should be connected as follows:
|
Red Lead |
+5 VDC to +15 VDC |
|
White Lead |
-5 VDC to –15 VDC |
|
Black Lead |
Power and Signal
Common (0 VDC) |
|
Brown Lead |
X-Axis Signal |
|
Orange Lead |
Y-Axis Signal |
|
Yellow Lead |
Z-Axis Signal |
For the Dynacube™-S,
the leads from the CA-04A cable should be connected as follows:
|
Red Lead |
+10 VDC |
|
White Lead |
Power Common (0
VDC) |
|
Black Lead |
Signal Common (+5
VDC Internally Generated Reference Voltage) |
|
Brown Lead |
X-Axis Signal |
|
Orange Lead |
Y-Axis Signal |
|
Yellow Lead |
Z-Axis Signal |
|