Over
      30 years of
      excellence...

 

     Applied Technology Associates                                                1300 Britt St SE, Albuquerque, NM  87123  USA                      Tel: (505) 767-1200  Fax: (505) 768-1379                              E-mail: ContactATA@aptec.com

  Our Company
 
About ATA About Us
  Contact ATA Contact Us
 
  ATA Sensors
 
Angular Rate Sensors Angular Rate Sensors
  Calibration & Testing
Calibration & Testing
  Application Notes Application Notes
  Export Information Export Information
 
  Optical Stabilization   
 
Optical Inertial Reference Units (IRU's) Optical IRU's
  Fast Steering Mirrors Fast Steering Mirrors
 
  Government Services
 
ATA's R & D Division R & D Services
  Military Test & Evaluation Test & Evaluation
 
  Resources
 
Site Map Site Map
  Current ATA Job Postings Press Releases
 
Current ATA Job Postings Job Postings
 
New Mexico Office for Space Commercialization (NMOSC) NM Spaceport Authority
  U.S. Department of State Office of Defense Trade Controls U.S. Dept. of State
  U.S. Department of Commerce Bureau of Industry & Security U.S. Dept. of Commerce
           
                      
We want your opinion!Feedback

                            Contact Us
           to discuss your
       specific applications!

 

 

 

 







































 

 

 

 





























 

 



 


Applications: 
ARS-01, ARS-01S, ARS-03, ARS-04E, ARS-07, ARS-09A, ARS-12

The ILC-01xx is a single sensor ILC unit which provides a DC/DC converter, and/or signal conditioning (velocity to acceleration), or amplification of the signal, or a combination of these three functions in a single compact machined aluminum box.  Units can only be configured at the time of manufacture since they are fully encapsulated with special epoxy resins for ruggedness and durability at assembly. Signal conversion and gain options are exclusive;  only one or the other may be specified.

 
 

 

  • As a power converter, the ILC-01 will allow the user to supply a single excitation voltage (typically +10 to12 Vdc) and provides a bipolar voltage (±13.2 Vdc) output to the sensor.  The order number for an ILC-01 for power conversion has the letter “D” as the ILC first option indicator. 
     

  • As a signal conditioner, it will covert the standard angular velocity output of the sensor to an angular acceleration signal. (The calibration data sheet provided with the ILC-01xA will specify the volts-per-volts output of the acceleration signal at 10 Hz. and at 100 Hz. This is a differential circuit. The gain at 100 Hz. will be ten times that at 10 Hz). The order number for an ILC for signal conversion  from velocity to acceleration has the letter “A” as the second ILC option indicator.
     

  • As an amplifier, the ILC will supply an amplified signal with gain of 1 to 1000 times normal signal output level.  Standard versions are available in 1, 10, 100, or 1000 times gain. The order number for an ILC for signal amplification of 10x has the letter “G” as the second ILC option indicator.  For gain of 100x, the letter “H” is specified.  For gain of 1000x, the letter “L” is specified.  (See examples below.)  Note that either gain or acceleration signal output can be supplied, not both.

Allowable ILC-01xx Order Numbers:

ILC-01-D 
ILC-01-A
ILC-01-DA
ILC-01-G
ILC-01-H
ILC-01-L
ILC-01-DG
ILC-01-DH
ILC-01-DL
ILC-01DF
ILC-01xx
Power conversion only
Signal conversion from velocity to acceleration only
Power conversion and Signal conversion from velocity to acceleration
Signal amplification of 10x only
Signal amplification of 100x only
Signal amplification of 1000x only
Power conversion and Signal amplification of 10x
Power conversion and Signal amplification of 100x only
Power conversion and Signal amplification of 1000x only
Power conversion and Signal Filtering  
Continued:  

Cables required with the ILC-01xx In-line-conditioner:

  • CA-02A      SENSOR to ILC-01 Cable (Not required with ARS-09A)  

  • CA-03A      ILC to user test equipment and power input cable

Check individual sensor order sheets to verify that the specific ILC-01xx model applies to the specific sensor you are ordering since some limitations apply.  Models ARS-01S cannot be used with power conversion options.  Model ARS-09A (not ARS-09) is required for use with ILC box.

 

Note: The CA-03A cable has AirBorn M series connectors at the ILC box and bare ends for the test equipment and power supply connections.  These require direct connection or customer supplied connectors at the test equipment and power supply.

 

 


All data is believed accurate at time of publication.  Specifications are subject to change without notice.
Copyright © 2002-2008  Applied Technology Associates. All rights reserved.  Revised:  02/23/2008