Applications:
Dynacube™
2-axis,
Dynacube™
Triaxial,
Dynacube™-S
Triaxial
The
DYNA-ILC
is
a
three
axis
ILC
unit
which
provides
a
DC/DC
converter,
or
a
signal
conditioning
(velocity
to
acceleration),
or
amplification
of
the
signal,
or
a
combination
of
these
three
functions
in
a
single
compact
machined
aluminum
box.
Units
can
only
be
configured
at
the
time
of
manufacture
since
they
are
fully
encapsulated
with
special
epoxy
resins
for
ruggedness
and
durability
at
assembly.
Signal
conversion
and
gain
options
are
exclusive;
only
one
or
the
other
may
be
specified.
The
unit
has
separate
input
and
output
connectors
for
each
of
the
three
sensors
plus
two
connectors
for
voltage
input/velocity
output
and
acceleration
output.
-
As
a
power
converter,
the
DYNA-ILC
will
allow
the
user
to
supply
a
single
excitation
voltage
(typically
+10
to12
Vdc)
and
provides
a
bipolar
voltage
(±13.2
Vdc)
output
to
the
three
sensors
in
the
triaxial
array.
The
order
number
for
an
ILC
for
power
conversion
has
the
letter
“D”
as
the
ILC
first
option
indicator.
(Power
converter
option
not
for
use
with
Dynacube-S)
-
As
a
signal
conditioner,
it
will
covert
the
standard
angular
velocity
output
of
the
three
sensors
to
angular
acceleration
signals.
(The
calibration
data
sheet
provided
with
the
DYNA-ILC
will
specify
the
volts-per-volts
output
of
the
acceleration
signal
at
10
Hz.
and
at
100
Hz.
This
is
a
differential
circuit.
The
gain
at
100
Hz.
will
be
ten
times
that
at
10
Hz.)
.
The
order
number
for
an
ILC
for
signal
conversion
from
velocity
to
acceleration
has
the
letter
“A”
as
the
second
ILC
option
indicator.
All
three
sensor
outputs
will
be
converted
unless
a
custom
order
is
specified.
-
As
an
amplifier,
the
ILC
will
supply
an
amplified
signal
with
gain
of
1
to
1000
times
normal
signal
output. Standard versions are
available
in
1,
10,
100,
or
1000
times
gain.
The
order
number
for
an
ILC
for
signal
amplification
from
1
to
10x
has
the
letter
“G”
as
the
second
ILC
option
indicator. For gain from 1 to
100x,
the
letter
“H”
is
specified.
For
gain
of
1000x,
the
letter
“L”
is
specified.
(See
examples
below.)
Note
that
either
gain
or
acceleration
signal
output
can
be
supplied,
not
both.
All
three
sensor
output
signals
will
be
amplified
at
the
same
amplification
rate
unless
a
custom
order
is
specified.
Allowable
DYNA-ILC
Order
Numbers
|
DYNA-ILC
-D
DYNA-ILC
-A
DYNA-ILC
-DA
DYNA-ILC
-G
DYNA-ILC
-H
DYNA-ILC
-L
DYNA-ILC
-DG
DYNA-ILC
-DH
DYNA-ILC
-DL
DYNA-ILC |
Power
conversion
only
Signal
conversion
from
velocity
to
acceleration
only
Power
conversion
and
Signal
conversion
from
velocity
to
acceleration
Signal
amplification
of
10x
only
Signal
amplification
of
100x
only
Signal
amplification
of
1000x
only
Power
conversion
and
Signal
amplification
of
10x
Power
conversion
and
Signal
amplification
of
100x
only
Power
conversion
and
Signal
amplification
of
1000x
only
continued.
|
Cables
required
with
the
DYNA-ILC-xx
In-line-
conditioner:
-
CA-05A
SENSOR
to
DYNA-ILC
Cable
-
CA-03A
DYNA-ILC
to
test
equipment
and
power
supply
-
CA-03AX
DYNA-ILC
to
test
equipment
for
acceleration
output
option
Check
individual
sensor
order
sheets
to
verify
that
the
specific
DYNA-ILC
model
applies
to
the
specific
sensor
you
are
ordering
since
some
limitations
apply.
Models
Dynacube-S
cannot
be
used
with
power
conversion
options.
Note:
The
CA-03A
and
CA-03AX
cables
have
AirBorn®
M
series
connectors
at
the
ILC
box
and
bare
ends
for
the
test
equipment
and
power
supply
connections.
These
require
direct
connection
or
customer
supplied
connectors
at
the
test
equipment
and
power
supply.
|
|