Scale
Factor
(Sensitivity)
--
The
standard
scale
factor
for
the
ARS-12
is
57,000
mV/(rad/sec).
We
can
provide
custom
scale
factors
to
order
over
a
range
of
values.
Any
other
desired
scale
factor
must
be
specified
in
mV/(rad/sec)
or
mV/(deg/sec).
Increasing
scale
factors
beyond
the
standard
value
will
result
in
a
reduction
in
frequency
range.
This
product
is
smaller
size
and
mass
than
the
ARS-11
but
has
a
higher
noise
floor
and
lower
resolution
with
the
same
sensitivity.
Range
--
The
output
signal
range
is
determined
by
dividing
the
maximum
output
voltage
by
the
scale
factor.
A
higher
scale
factor
will
result
in
a
more
limited
range.
A
standard
ARS-12
with
a
57,000
mV/(rad/sec)
scale
factor
and
an
output
power
voltage
of
±10
V
will
have
an
angular
velocity
range
of
±
0.175
rad/sec.
Input
Voltages
(Excitation)
--
Standard
input
voltages
of
+
5/-5
Vdc
to
+15/-15
Vdc
are
used
for
the
ARS-12.
When
the
applications
require
operation
from
a
single
power
source
such
a
+12
Vdc,
an
ILC
can
be
used
to
generate
the
dual
voltage
inputs
to
the
sensor.
Signal
Conditioning
and
Power
Supply
Requirements
--
the
ARS-12
may
be
operated
without
a
separate
power
regulator
or
in-line
signal
conditioning
unit
if
the
standard
customer
power
supply
is
well
regulated
and
without
noise,
and
if
the
sensor
output
cables
are
of
proper
impedance,
not
more
than
15
to
20
feet
in
length,
and
not
subject
to
induced
noise
from
external
emi
sources.
ATA
Sensors
supplies
optional
cables
for
the
ARS-12
which
have
the
proper
connectors,
use
Teflon®
insulated
wire
with
twisted
pairs
and
heavy
metal
shielding
to
minimize
noise.
Cables
and
Connectors
--
Two
cable
connection
options
are
offered
for
the
ARS-12.
The
cable
CA-01
is
specified
when
no
ILC
is
used.
Standard
cable
lengths
are
approximately
7
meters
(23
feet)
and
this
is
supplied
with
the
sensor
mating
connector
on
one
end
and
un-terminated
pigtail
at
the
other
to
allow
for
the
customer
to
add
their
own
connection
to
measurement
equipment.
The
cable
CA-02
is
specified
when
an
ILC
box
will
be
used.
This
is
a
5.5-meter
cable,
which
goes
from
the
sensor
connector
to
the
ILC
box. The ILC box utilizes
a
4-pin
military
specification
AirBorn®
connector
(male)
MA-211-004-113-0000.
The
output
side
of
the
ILC
box
uses
a
corresponding
CA-03
cable,
which
is
1.5
meters
in
length,
has
an
AirBorn®
connector
at
the
ILC
box
end,
and
a
pigtail
at
the
other
end
to
allow
customer
interface
connectors
to
be
added.
Custom
machined
connector
housing
allows
the
connector
to
be
locked
to
the
ILC
using
screws
provided.
In-Line-Converter
(ILC)
--
modules
are
offered
by
ATA
Sensors
to
provide
a
complete
measurement
solution
for
power
regulation
and
signal
conditioning
/
amplification.
The
ILC
modules
applicable
to
the
ARS-12
are:
ILC-01xx
--
This
is
a
single
sensor
ILC
unit
which
provides
a
DC/DC
converter
and
signal
conditioning
/
amplification
in
a
single
unit
or
a
combination
of
these
three
functions.
Units
can
only
be
configured
at
the
time
of
manufacture,
since
they
are
fully
encapsulated
with
special
epoxy
resins
for
ruggedness
and
durability
at
assembly.
Signal
conversion
and
gain
options
are
exclusive;
only
one
or
the
other
may
be
specified.
-
As
a
power
converter,
the
ILC
will
allow
the
user
to
supply
a
single
excitation
voltage
(typically
+10
to12
Vdc)
and
provides
a
bipolar
voltage
(±13.2
Vdc)
output
to
the
sensor.
The
order
number
for
an
ILC
for
power
conversion
has
the
letter
“D”
as
the
ILC
first
option
indicator.
If
no
power
conversion
is
desired,
the
letter
“N”
is
specified.
-
As
a
signal
conditioner,
it
will
covert
the
standard
angular
velocity
output
of
the
sensor
to
an
angular
acceleration
signal.
(The
calibration
data
sheet
provided
with
the
ILC-01DGA
will
specify
the
volts-per-volts
output
of
the
acceleration
signal
at
10
Hz.
and
at
100
Hz.
This
is
a
differential
circuit.
The
gain
at
100
Hz.
will
be
ten
times
that
at
10
Hz).
The
order
number
for
an
ILC
for
signal
conversion
from
velocity
to
acceleration
has
the
letter
“A”
as
the
second
ILC
option
indicator.
-
As
an
amplifier,
the
ILC
will
supply
an
amplified
signal
with
gain
of
1
to
1000
times
normal
signal
output.
Standard
versions
are
available
in
1,
10,
100,
or
1000
times
gain.
The
order
number
for
an
ILC
without
additional
gain
(1x)
is
“F”.
The
order
number
for
an
ILC
for
signal
amplification
from
1
to
10x
has
the
letter
“G”
as
the
second
ILC
option
indicator.
For
gain
from
1
to
100x,
the
letter
“H”
is
specified.
For
gain
of
1000x,
the
letter
“L”
is
specified.
(See
examples
below.)
Note
that
either
gain
or
acceleration
signal
output
can
be
supplied,
not
both.
ILC-03xx
--
This
is
a
three
channel
ILC
with
functions
equivalent
to
the
ILC-01
functions
and
is
designed
to
support
a
triaxial
array
with
a
single
box.
The
unit
has
separate
input
and
output
connectors
for
each
of
the
three
sensors
plus
two
connectors
for
voltage
input/velocity
output
and
acceleration
output.
See
the
section
on
triaxial
units
for
ILC-03
options.
Allowable
ILC
Order
Numbers
for
ARS-12:
ILC-01-DF
ILC-01-NA
ILC-01-DA
ILC-01-NG
ILC-01-NH
ILC-01-NL
ILC-01-DG
ILC-01-DH
ILC-01-DL |
Power
conversion
only
Signal
conversion
from
velocity
to
acceleration
only
Power
conversion
and
Signal
conversion
from
velocity
to
acceleration
Signal
amplification
of
10x
only
Signal
amplification
of
100x
only
Signal
amplification
of
1000x
only
Power
conversion
and
Signal
amplification
of
10x
Power
conversion
and
Signal
amplification
of
100x
only
Power
conversion
and
Signal
amplification
of
1000x
only |
On
a
custom
order
basis,
the
ARS-12
can
be
supplied
in
a
Triaxial
kit,
which
has
three
ARS-12
sensors
and
a
mounting
block
to
make
the
triaxial
system.
This
can
also
have
linear
accelerometers
added
to
make
a
6
degree-of-freedom
system.
|