Over
      30 years of
      excellence...

 

     Applied Technology Associates                                                1300 Britt St SE, Albuquerque, NM  87123  USA                      Tel: (505) 767-1200  Fax: (505) 768-1379                              E-mail: ContactATA@aptec.com

  Our Company
 
About ATA About Us
  Contact ATA Contact Us
 
  ATA Sensors
 
Angular Rate Sensors Angular Rate Sensors
  Calibration & Testing
Calibration & Testing
  Application Notes Application Notes
  Export Information Export Information
 
  Optical Stabilization   
 
Optical Inertial Reference Units (IRU's) Optical IRU's
  Fast Steering Mirrors Fast Steering Mirrors
 
  Government Services
 
ATA's R & D Division R & D Services
  Military Test & Evaluation Test & Evaluation
 
  Resources
 
Site Map Site Map
  Current ATA Job Postings Press Releases
 
Current ATA Job Postings Job Postings
 
New Mexico Office for Space Commercialization (NMOSC) NM Spaceport Authority
  U.S. Department of State Office of Defense Trade Controls U.S. Dept. of State
  U.S. Department of Commerce Bureau of Industry & Security U.S. Dept. of Commerce
           
                      
We want your opinion!Feedback

                            Contact Us
           to discuss your
       specific applications!

 

 

 

 







































 

 

 

 





























 

 




                                                          Wiring Connections

Scale Factor (Sensitivity) -- The standard scale factor for the ARS-04 is 100 mV/(rad/sec).  We can provide optional custom scale factors to order over a range of values.  Any other desired scale factor must be specified in mV/(rad/sec) or mV/(deg/sec).  Increasing scale factors beyond the standard value will result in a reduction in frequency range.

Range -- The output signal range is determined by dividing the maximum output voltage by the scale factor.  A higher scale factor will result in a more limited range. A standard ARS-04 with a 100 mV/(rad/sec) scale factor and an output power voltage of ±10 V will have an angular velocity range of ± 100 rad/sec.

Input Voltages (Excitation) -- Standard input voltages of + 5/-5 Vdc to +15/-15 Vdc are used for the ARS-04.  When the applications require operation from a single power source such a +12 Vdc, an ILC can be used to generate the dual voltage inputs to the sensor.

Signal Conditioning and Power Supply Requirements -- The ARS-04 may be operated without a separate power regulator or in-line signal conditioning unit if the standard customer power supply is well regulated and without noise, and if the sensor output cables are of proper impedance, not more than 15 to 20 feet in length, and not subject to induced noise from external emi sources. ATA Sensors supplies optional cables for the ARS-04E which have the proper connectors, use Teflon® insulated wire with twisted pairs and heavy metal shielding to minimize noise.  No cables are supplied for the ARS-04R.

Cables and Connectors -- Two cable connection options are offered for the ARS-04E. The cable CA-01 is specified when no ILC is used.  Standard cable lengths are approximately 7 meters (23 feet) and this is supplied with the sensor mating connector on one end and un-terminated pigtail at the other to allow for the customer to add their own connection to measurement equipment.

The cable CA-02 is specified when an ILC box will be used.  This is a 5.5 meter cable which goes from the sensor connector to the ILC box.  The ILC box utilizes a 4-pin military specification AirBorn® connector (male) MA-211-004-113-0000.  The output side of the ILC box uses a corresponding CA-03 cable which is 1.5 meters in length, has an AirBorn® “M” series connector at the ILC box end, and a pigtail at the other end to allow customer interface connectors to be added.  Custom machined connector housing allow the connector to be locked to the ILC using screws provided.

 


Product Specifications


DYNAMIC

·         ARS-04 Range                                         ±100 Radian/sec (±5,750 degree /sec)

      (Peak to Peak @ ±15 Vdc dual power supply)

·         Sensitivity                                                 100 mV/radian/sec (1.7mV/degree/sec)

      (Measured @ 10 Hz)

·         Bandwidth                                                 1.0 to 1000 Hz

·         Cross-axis Angular Error                               < 2%

·         Linear Acceleration Sensitivity                      <0.002 radians/sec/g (<0.1 degree/sec/g)

·         Voltage Noise PSD                                      3.0 x 10 (-11) V(2) / Hz

      (Power spectral density flat to angular velocity over specified bandwidth)

·         Noise Equivalent Angle                                 < 0.1 microradians (rms)

·         Non-linearity                                              <0.1%

·         Temperature Coefficient                              < 0.5% Scale Factor / ºC

      (Percent change in Scale Factor per ºC @ 100 Hz)

 

ELECTRICAL

·         Excitation Voltage                                      ±5.0 to ±15.0 Vdc

·         Power Dissipation                                       < 0.3 Watts

·         Output Impedence                                               < 100 Ohms

·         Grounding                                                 Case (isolated from signal return)

      Signal return isolated internally from case to prevent ground loops

 

MECHANICAL

·         Diameter                                                    25.4 mm (1.00 inches)

·         Height                                                       33.0 mm (1.3 inches)

·         Weight                                                      100 gm (3.5 oz)

·         Case material                                              Stainless Steel 430

·         Mounting                                                    #4 - 40 x  ¼  inch (3)  2Nm (18 inch-lb)

 

ENVIRONMENTAL

·         Temperature- operating                                -35 to + 60ºC (-31 to +140ºF )

·         Temperature- non-operating                          -60 to + 100ºC (-51 to +212ºF )

·         Humidity:                                                   Unaffected- Hermetically sealed unit

·         Linear Acceleration Max operating                   500 g any axis

      ( Peak, 100Hz half sine)

·         Linear Acceleration, Max survivable                 800 g any axis

      (Not including cables)


No moving parts, Dynamic range >100dB, Hermetically sealed units, Low power consumption, Low cross axis angular sensitivity, Low linear acceleration sensitivity, Integral electronics/low noise, High survival shock limits, Superior applications support, One-year warranty against defects in materials and workmanship on sensors, 90 days on cables.  All data is believed correct at time of publication.  Specifications are subject to change without notice.  Requires interface cable CA-01, ARS-12ds/8.98.

 

 

 


All data is believed accurate at time of publication.  Specifications are subject to change without notice.
Copyright © 2002-2011  Applied Technology Associates. All rights reserved.  Revised:  08/11/2011